Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
EDITORIAL BOARD
Editorial I
Editorial II
Original Article
Review
Review Article
Systematic Review
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
EDITORIAL BOARD
Editorial I
Editorial II
Original Article
Review
Review Article
Systematic Review
View/Download PDF

Translate this page into:

Original Article
4 (
2
); 156-167

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate

Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Disclaimer:
This article was originally published by Qassim University and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Abstract Background This in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex in mandibular posterior teeth. Methods Fourteen human cadaver mandibles with retained molars were selected. These molars were prepared for access to the canals and an endodontic file #10 was introduced into the canal at one of the three random distances from the apex of the tooth. At each distance from the apex and at the apex of the tooth, images were made with two different image receptors; DenOptix storage phosphor plates and Gendex CCD sensor. Six raters viewed all the images for identification of the radiographic apex of the tooth and the tip of the endodontic file. Images were displayed randomly under standardized conditions. To assess intra-rater reliability, all the examiners viewed a subset of randomly selected images again after a time period of one week, inter rater reliability was also assessed. At the end of the study, teeth were extracted and the length of the canals measured to obtain a gold standard. Results T-test revealed a significant main effect for the type of image, indicating that raters’ error in identifying structures of interest was significantly higher for Denoptix storage phosphor plates. Conclusion The results of the study clearly reveal that Gnedex CCD produce most reliable images for Root Canal working length estimation when compared with Denoptix SPP.


Fulltext Views
234

PDF downloads
83
View/Download PDF
Download Citations
BibTeX
RIS
Show Sections