Laser micro-grooved, Arginine-Glycine-Apspartic acid (RGD) coated dental implants, a 5 years radiographic follow-up

Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Disclaimer:
This article was originally published by Qassim University and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Objectives: This work has utilized laser direct writing to produce 10 microns wide uniform grooves on the surface of custom made titanium (Ti-6Al-4V) dental implants, and the tri-peptide RGD coating to produce a micromechanical and a chemical union with the tissues around the implant crest module and minimize crestal bone loss. The aim of this study was to follow these implants radiographically after five years of service under a mandibular overdenture. Methodology: Standardized digital periapical radiographs and the computer software “Image J” were used to evaluate the bone density profile and vertical bone loss along the mesial and distal sides of the implants used in this study. Results:The results of this study demonstrated less vertical bone loss and higher bone density profiles next to the laser micro-grooved implants coated with the RGD than those only having the laser micro-grooves. Conclusion: The RGD coating has improved the bone density profile and reduced the vertical bone loss around the studied dental implants. However, further studies are needed to compare the effects of the laser micro-grooves versus other uniform or non uniform surface features; also, the RGD coating should be compared to other biomimetic surface coating materials.

Keywords

titanium
dental implants
laser micro-grooving
laser micromachining
direct laser writing
RGD.