Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
EDITORIAL BOARD 2026-20-1
Editorial I
Editorial II
Original Article
Review
Review Article
Systematic Review
Systematic Review and Meta-Analysis
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Case Series
Editorial
EDITORIAL BOARD 2026-20-1
Editorial I
Editorial II
Original Article
Review
Review Article
Systematic Review
Systematic Review and Meta-Analysis
View/Download PDF

Translate this page into:

Original Article
9 (
3
); 249-256

Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms

Licence
This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
Disclaimer:
This article was originally published by Qassim University and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Objectives: The purpose of this study is to provide insight into how students are exposed to indoor bio-aerosols in the dormitory rooms and to figure out the major possible factors that govern the contamination levels. Methodology: The Bio-aerosols concentration level of indoor air of thirty dormitory rooms of Jimma University was determined by taking 120 samples. Passive air sampling technique; the settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Results: The range of bio-aerosols contamination detected in the dormitory rooms was 511- 9960 CFU/m3 for bacterial and 531- 6568 CFU/m3 for fungi. Based on the criteria stated by WHO expert group, from the total 120 samples 95 of the samples were above the recommended level. The statistical analysis showed that, occupancy were significantly affected the concentrations of bacteria that were measured in all dormitory rooms at 6:00 am sampling time (p-value=0.000) and also the concentrations of bacteria that were measured in all dormitory rooms were significantly different to each other (p-value=0.013) as of their significance difference in occupancy (p-value=0.000). Moreover, there were a significant different on the contamination level of bacteria at 6:00 am and 7:00 pm sampling time (p=0.015), whereas there is no significant difference for fungi contamination level for two sampling times (p= 0.674). Conclusion: There is excessive bio-aerosols contaminant in indoor air of dormitory rooms of Jimma University and human occupancy produces a marked concentration increase of bacterial contamination levels and most fungi species present into the rooms air of Jimma University dormitory were not human-borne.

Keywords

indoor air
bio-aerosol
bacteria
fungi
sedimentation technique
dormitory room

Fulltext Views
305

PDF downloads
122
View/Download PDF
Download Citations
BibTeX
RIS
Show Sections