Translate this page into:
Sonographic Diagnosis of Infantile Hypertrophic Pyloric stenosis- Use of Simultaneous Grey-scale & Colour Doppler Examination
-
Received: ,
Accepted: ,
This article was originally published by Qassim University and was migrated to Scientific Scholar after the change of Publisher.
Abstract
Objective: To evaluate the accuracy of Ultrasound in the diagnosis of Infantile Hypertrophic Pyloric stenosis, especially with simultaneous use of grey-scale & colour doppler examination of pylorus. Methods: Fifty two infants with suspected Infantile Hypertrophic Pyloric stenosis (IHPS) were evaluated with grey-scale and colour Doppler examination. The sonographic findings were categorized as positive IHPS, negative IHPS and equivocal cases. Positive songraphic findings in 21 infants (40%) were confirmed at surgery. Negative sonographic findings in 27 infants (52%) were followed by ward chart reviews. Results: Sensitivity, Specificity and Accuracy of grey-scale & colour doppler examination for the diagnosis of IHPS were 100%. Conclusion: Sonography is the method of choice for the diagnosis of IHPS. Simultaneous greyscale and colour Doppler examination of pylorus for suspected IHPS is more accurate than simple grey-scale sonography.